CSA 221421
CSA 26CA80263367X
CLI, DIV 1, GRP A, B, C and D
CLII, DIV 1, GRP E, F and G; CLIII
Ex ia IIC T3-T4 Ga
Ex ib IIIC T135°C...T156°C Db
CLI, ZN 0, AEx ia IIC T3-T4 Ga
ZN 21, AEx ib IIIC T135°C...T156°C Db
T3: Ta = –40°C to +121°C
T4: Ta = –40°C to +80°C
T156°C: Ta = – 40°C to +121°C
T135°C: Ta = – 40°C to +80°C
Install per drawing INS10187
Refer to product manual MNX10127
200 ft (61 m) Maximum Allowable Integral Cable Length
Approved Cabling: CB102, CB103*, CB111, CB190*, CB193*, CB296 (*Approved for Use in T4 Applications Only)
Requires One IS111-1B Intrinsic Safety Barrier Per Sensor
IECEx SIR 15.0060X
Ex ia IIC T3-T4 Ga
Ex ib IIIC T135°C … T156°C Db
Ex ia I Ma
T3: Ta @ -40°C to +121°C
T4: Ta @ -40°C to +80°C
Mining Group I: Ta @-40°C to +121°C
T156°C: Ta @ -40°C to +121°C
T135°C: Ta @ -40°C to +80°C
Install per drawing INS10210
Refer to product manual MNX10134
Sira 15ATEX2152X
Ex ia IIC T3 -T4 Ga
T3: Ta @ -40°C to +121°C
T4: Ta @ -40°C to +80°C
Ex ib IIIC T135°C … T156°C Db
T156°C: Ta @ -40°C to +121°C
T135°C: Ta @ -40°C to +80°C
Ex ia I Ma
Ta @-40°C to +121°C
Install per drawing INS10211
Refer to product manual MNX10135
Connector Exit Entity Parameters:
Ui = 28 Vdc, li = 120 mA, Pi = 1W, Ci = 28nF, Li = 0µH
Integral Cable Entity Parameters
Ui = 28 Vdc, li = 120 mA, Pi = 1W, Ci = 40nF, Li = 40.2µH